{"product_id":"huawei-s110-24lp2sr-ekitengine-unmanaged-poe-switch-24-port-gigabit-ethernet-2-sfp-ports","title":"Huawei S110-24LP2SR eKitEngine Unmanaged PoE+ Switch, 24 Port Gigabit Ethernet + 2 SFP ports","description":"\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003eOverview\u003c\/h2\u003e\n\n\u003cdiv class=\"idp-ltr-html-tablenoborder\"\u003e\n\u003cspan class=\"idp-ltr-html-tablecap\"\u003e\u003cspan class=\"idp-ltr-html-tablenumber\"\u003eTable 4-21\u003c\/span\u003e Basic information about the S110-24LP2SR\u003c\/span\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" rules=\"all\" summary=\"\"\u003e\n\t\u003cthead align=\"left\"\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth valign=\"top\" width=\"50%\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"50%\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003eDescription\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003eS110-24LP2SR (24*10\/100\/1000BASE-T ports, 2*GE SFP ports, PoE+, AC power)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003ePart Number\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003e98012198\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003eModel\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"50%\"\u003eS110-24LP2SR\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003eComponents\u003c\/h2\u003e\n\n\u003cdiv class=\"idp-ltr-html-fignone\" id=\"0000001603167009__figd0e3346\"\u003e\n\u003cspan class=\"idp-ltr-html-figcap\"\u003e\u003cspan class=\"idp-ltr-html-figurenumber\"\u003eFigure 4-8\u003c\/span\u003e S110-24LP2SR appearance\u003c\/span\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" decoding=\"async\" src=\"https:\/\/gfx2.senetic.com\/gfx\/products_description\/98012198\/S110-24LP2SR-image-1.png\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-simpletableborder\" summary=\"\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"4.504504504504505%\"\u003e1\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"45.4954954954955%\"\u003ePWR indicator\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"4.504504504504505%\"\u003e2\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"45.4954954954955%\"\u003eTwenty-four GE PoE+ electrical ports\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e3\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eElectrical port indicator\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e4\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eTwo GE optical ports\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e5\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eOptical port indicator\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e6\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003ePort mode switch button\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\t\t\t\u003cp\u003eStandard Mode: All ports are in the same VLAN, and the flow control function is enabled.\u003c\/p\u003e\n\n\t\t\t\u003cp\u003ePort Isolation: All downlink ports are isolated from each other and cannot communicate with each other. Downlink ports can communicate only with uplink ports. (The last two downlink electrical ports are not isolated.) Uplink ports are not isolated or aggregated.\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eUplink Aggregation: Two uplink optical ports are aggregated into a trunk interface. Eth-Trunk supports load balancing only based on source physical ports.\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eFlow Control Disabling: All ports are in the same VLAN and flow control is disabled.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e7\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003ePort indicator status switch button\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\t\t\t\u003cp\u003ePort status: The port indicator indicates the data transmission status of the port.\u003c\/p\u003e\n\n\t\t\t\u003cp\u003ePoE status: The port indicator indicates the PoE status of the port.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e8\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGround screw\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e9\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eAC socket\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\t\t\t\u003cp\u003eUse the power cable delivered with the device.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e–\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003e–\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003ePorts\u003c\/h2\u003e\n\n\u003cdiv class=\"idp-ltr-html-tablenoborder\"\u003e\n\u003cspan class=\"idp-ltr-html-tablecap\"\u003e\u003cspan class=\"idp-ltr-html-tablenumber\"\u003eTable 4-22\u003c\/span\u003e Ports on the S110-24LP2SR\u003c\/span\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" rules=\"all\" summary=\"\"\u003e\n\t\u003cthead align=\"left\"\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth valign=\"top\" width=\"25%\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"25%\"\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"25%\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"25%\"\u003e\u003cstrong\u003eAvailable Components\u003c\/strong\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eGE PoE+ electrical port\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eRJ45\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eA GE PoE+ electrical port sends and receives service data at 10\/100\/1000 Mbit\/s.\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cp\u003eThe port supports the PoE function.\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eEthernet cable\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eGE optical port\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eSFP\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003eA GE optical port can send and receive data at 100\/1000 Mbit\/s.\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"25%\"\u003e\n\t\t\t\u003cul class=\"idp-ltr-html-ul\"\u003e\n\t\t\t\t\u003cli class=\"idp-ltr-html-li\"\u003eFE SFP\/eSFP optical modules (only optical modules with transmission distances less than or equal to 15 km are supported)\u003c\/li\u003e\n\t\t\t\t\u003cli class=\"idp-ltr-html-li\"\u003eGE eSFP optical modules (only optical modules with transmission distances less than or equal to 10 km are supported)\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003eIndicators and Buttons\u003c\/h2\u003e\n\n\u003cdiv class=\"idp-ltr-html-tablenoborder\"\u003e\n\u003cspan class=\"idp-ltr-html-tablecap\"\u003e\u003cspan class=\"idp-ltr-html-tablenumber\"\u003eTable 4-23\u003c\/span\u003e Description of indicators on the device\u003c\/span\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" rules=\"all\" summary=\"\"\u003e\n\t\u003cthead align=\"left\"\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth valign=\"top\" width=\"16.78167816781678%\"\u003eIndicator\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"13.02130213021302%\"\u003eColor\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"11.87118711871187%\"\u003eStatus\u003c\/th\u003e\n\t\t\t\u003cth valign=\"top\" width=\"58.32583258325832%\"\u003eDescription\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd rowspan=\"2\" valign=\"top\" width=\"16.78167816781678%\"\u003ePWR indicator\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"13.02130213021302%\"\u003e–\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"11.87118711871187%\"\u003eOff\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"58.32583258325832%\"\u003eThe device is powered off.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGreen\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eSteady on\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eThe power supply is normal.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd rowspan=\"3\" valign=\"top\" width=\"16.78167816781678%\"\u003ePort indicator (Port status)\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"13.02130213021302%\"\u003e–\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"11.87118711871187%\"\u003eOff\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"58.32583258325832%\"\u003eThe port is not connected or has been shut down.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGreen\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eSteady on\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eA link has been established on the port.\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\n\t\t\t\u003cp\u003e \u003c\/p\u003e\n\n\t\t\t\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\t\t\t\u003cp\u003eDuring device startup, all port indicators are steady green for about 2 seconds and then off, indicating that service initialization is complete.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGreen\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eBlinking\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eThe port is sending or receiving data.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd rowspan=\"3\" valign=\"top\" width=\"16.78167816781678%\"\u003ePort indicator (PoE status)\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"13.02130213021302%\"\u003e–\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"11.87118711871187%\"\u003eOff\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\" width=\"58.32583258325832%\"\u003eThe port is not supplying PoE power.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGreen\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eSteady on\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eThe port is supplying power to the connected PD.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eGreen\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eBlinking\u003c\/td\u003e\n\t\t\t\u003ctd valign=\"top\"\u003eThe PoE power of the device is insufficient, and the port cannot provide power to the PD.\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003ePower Supply System\u003c\/h2\u003e\n\n\u003cp\u003eThe device uses the power adapter delivered with the device to supply power to the device and the connected PD. The power adapter can provide 124 W PoE power, which ensures full PoE power on 8 ports in compliance with 802.3af or on 4 ports in compliance with 802.3at.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"idp-ltr-html-section\"\u003e\n\u003ch2 class=\"idp-ltr-html-sectiontitle\"\u003eHeat Dissipation System\u003c\/h2\u003e\n\n\u003cp\u003eThe device has no fans and uses natural heat dissipation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"huawei","offers":[{"title":"Default Title","offer_id":46530269118566,"sku":"S110-24LP2SR","price":10450.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/6514\/4166\/files\/S110-24LP2SR.webp?v=1786991003","url":"https:\/\/eservice-store.com\/products\/huawei-s110-24lp2sr-ekitengine-unmanaged-poe-switch-24-port-gigabit-ethernet-2-sfp-ports","provider":"eService Store","version":"1.0","type":"link"}